VGS Series Power Supplies

By CUI Inc 903

VGS Series Power Supplies

CUI Inc's VGS series of highly efficient, compact, internal switching power supplies feature a no-load power consumption of <0.5 W. The series includes 25, 50, 75, and 100 W versions with cooling by free air convection, efficiencies of up to 89%, and is very compact with the 25 W model (VGS-25) measuring 3.09 x 2.00 x 1.11 inches. It is ideal for a wide range of applications where energy consumption is a consideration including industrial control, networking, automation, and test & measurement equipment.

VGS Series offers a universal input (88-264 Vac) and single output voltages of 3.3, 5, 12, 15, 24, and 48 Vdc. Other features include an LED indicator when power is on, 105 °C long life electrolytic capacitors, and an operating temperature range of -25 °C to 70 °C, derating linearly from 100% load at 50 °C. Protections include short circuit, overload, over-voltage, and brown-out (low ac input voltage). All models are approved to UL, cUL, and TUV safety standards and come with a three year warranty.

Features

  • Green design, no-load power consumption <0.5 W
  • Universal ac input / full range
  • Short circuit, overload, over-voltage, brown-out (low ac input voltage) protected
  • High-efficiency, long life, high reliability
  • 105°C long life electrolytic capacitors
  • High operating temperature up to 70°C
  • LED indicator for power on
  • Cooling by free air convection
  • Able to withstand 5G vibration
  • 3 year warranty

Specifications

Input

parameter conditions/description min nom max units
input voltage rating 125 373 V dc
   88 264 V ac
input current at 115 V ac 0.7 A
  at 230 V ac 0.35 A
inrush current at 230 V ac, cold start 30 A

Output

parameter conditions/description min nom max units
voltage tolerance 3.3 V -3 +3 %
  5V -2 +2 %
  12 V, 15 V, 24 V, 48 V -1 +1 %
voltage adjust range -10 +10 %
ripple & noise (20MHz BW) 3.3 V, 5 V 100 mV RMS
  12 V, 15 V, 24 V 120 mV RMS
  48 V 200 mV RMS
setup rise hold time setup: 800 ms, rise: 50 ms / 230 V ac setup: 1000 ms, rise: 65 ms / 115 V ac
  hold: >32 ms / 230 V ac, >10 ms / 115 V ac
temperature coefficient at 0~50°C ±0.03 %/°C
short circuit protection continuous
line regulation3 -0.5 +0.5 %
load regulation4 ±2 %
over voltage protection latch-off mode 115 150 %
over current protection hiccup mode, auto recovery 110 %